Eternal Step | Wood
Eternal Step | Wood
Our Eternal step Wood safety vinyl floors contain natural designs that provide a warm ambiance to all areas. The wood designs have a clear and sharp visual thanks to the use of the almost invisible Step Crystals, which also guarantee lifetime slip resistance.
Gauge: 2.0 mm (0.080")
Size: 79" 82'
60 Sq. Yds.
307 Lbs.
The Eternal step Wood palette of 11 colorways contains our most popular bestselling colors alongside new abstract woods and all-over designs.
1.4 Physical Characteristics: (dimensions are approximate)
Gauge --------------- 0.080” (2.0 mm)
Width --------------- 79” (2 meters)
Wear layer --------- 0.0275” (0.7 mm)
Length -------------- 82’ (25 meters)
Roll Size ------------ 60 yards2 (50 meters2 )
2. PRODUCT PERFORMANCE AND TECHNICAL DATA 2.1 Reference Specification: Meets or exceeds all technical requirements as set forth in ASTM F 1303, Standard Specification for Vinyl Sheet Floor Covering with Backing Type 1, Grade 1, Class B Backing 2.2 Environmental: Compliant with CHPS 01350 requirements for VOC emissions and indoor air quality. Contributes to the following LEED® v4 credits: Materials & Resources Credit 4, Option 1: See Forbo’s LEED v4 sheet for additional information. Credit 4, Option 2: Recycled Content (15% Pre-Consumer) Prerequisite 2: 100% Recyclable Core and Stopper Indoor Environmental Quality Credit 2: Low-Emitting Materials (www.chps.net) Credit 2: Low-Emitting Materials (Adhesives comply with SCAQMD Rule #1168) 2.3 Static Load Limit: 850 pounds per square inch when tested in accordance with ASTM F 970-00, Standard Test Method for Static Load Limit. 2.4 Slip Resistance: Meets or exceeds A.D.A. recommendation of 0.6 for flat surfaces and 0.8 for inclined surfaces when tested in accordance with ASTM D 2047, Standard Test Method for Static Coefficient of Friction. 2.5 Castor Resistance: Suitable for office chairs with castors when tested in accordance with EN 425, Castor Chair Test. 2.6 Fire Testing: Class 1 when tested in accordance with ASTM E 648/NFPA 253, Standard Test Method for Critical Radiant Flux. Meets 450 or less when tested in accordance with ASTM E 662/ NFPA 258, Standard Test Method for Smoke Density. 2.7 Chemical Resistance: (Exposure Time: One Hour) Acetic Acid (5%) ---------------------------------------- No Change Isopropyl Alcohol (70%) ------------------------------ No Change Sodium Hydroxide (5%) ------------------------------ No Change Hydrochloric Acid (5%) ------------------------------- No Change Sulfuric Acid ------------------------------------------ Color Change Ammonia (5%) ------------------------------------------ No Change Bleach ----------------------------------------------------- No Change Phenol (5%) ---------------------------------------------- No Change Gasoline -------------------------------------------------- No Change Kerosene ------------------------------------------------- No Change Mineral Oil, Olive Oil ---------------------------------- No Change Methalyne Blue ----------------------------------------- No Change Iodine, Betadine ---------------------------------------- No Change Gel-Based Hand Sanitizer ---------------------------- No Change Hair Dye --------------------------------------------------- No Change Tested in accordance with ASTM F 925, Standard Test Method for Resistance to Chemicals of Resilient Flooring.